High Frequency Pure Sine Wave Three Phase Online UPS 10-80kVA
Key Features:
1. Up to 8 units in parallel
2. DSP control
3. Double CPU control
4. Modularize
5. Battery can be sharing
6. Advanced operation mode
7. Manual maintenance bypass
8. Wide input voltage range
7. High output power factor
9. Strong environmental adaptability
10. Advanced battery management
11. N+X parallel redundancy
12. Compatible with generator
13. Strong shock resistance ability
14. EPO function
15. Full protection against over-discharge, overcharge, over load.
LBS Function:
LBS function supports the two independent input to improve the reliability of the system.
High reliability:
True on-line static bypass technology, to provide strong overload and fault protection device.
Internal manual maintenance bypass, further improve the reliability of continuous operation of the load.
Network management humanity:
Communicate with PC by RS232.
Use SNMP adapter, UPS can realize remote network management function.
Optimized battery performance:
Intelligent battery management function (ABM)
Automatically convert to constant-current constant-voltage charging technology.
Parallel Configuration of up to 8 units of UPS Manfacturer 1GP9332C 10-120kVA:
Can parallel 8 units UPS;
Parallel UPS units can share a battery pack;
Non-fixed master/slave parallel
Application:
Large-medium computer data center, industrial process and other mission-critical equipment
Model | HL10K3/3 | HL20K3/3 | HL30K3/3 | HL40K3/3 | HL60K3/3 | HL80K3/3 | HL100K3/3 | HL120K3/3 | HL160K3/3 | HL200K3/3 | HL300K3/3 | HL400K3/3 |
| | | | | | | | | | | | |
| | | | | | | | | | | | |
NominaHL capacity(KVA) | 10KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | 100KVA | 120KVA | 160KVA | 200KVA | 300KVA | 400KVA |
| | | | | | | | | | | | |
| |
Work principle | Pure sine wave onLine |
| |
| |
Phase | 3 phase +N+G |
| |
| |
Input power factor | >0.8, >0.95 |
| |
| | |
Rectifier | Nominal input voltage | 220/380VAC, 230/400VAC, 240/415VAC |
| | |
| | |
| Range | ±25% |
| | |
| | |
| NominaHL input frequency | 50Hz±10%, 60Hz±10% |
| | |
| | |
| Output ripple | < 2 % |
| | |
| | |
| Soft start | 0 ~ 100% 5s |
| | |
| | |
Charge | Charge mode | Constant current to constant voLtage, with temp compensation; with auto change |
| | |
| | |
| Float voltage | 432VDC |
| | |
| | |
| Boost voltage | 464VDC |
| | |
| | |
| Temperature compensation voltage | 3mV/°C(monomer) |
| | |
| | |
| Charge current | 0.1C ( automaticaLLy change according to battery capacity ) |
| | |
| | |
| Charge power | 20 % of rated capacity |
| | |
| | |
Battery | Battery type | Maintenance-free Lead acid battery |
| | |
| | |
| Battery capacity | 7 ~ 999AH settabHLe(according to the capacity) |
| | |
| | |
| Battery number | 32pcs 12V, or 192pcs 2V ( nominal voltage 384VDC ) |
| | |
| | |
Inverter | Phase | 3 phase +N |
| | |
| | |
| Rated power | Rated capacity×0.8 |
| | |
| | |
| NominaHL voHLtage | 220/380VAC, 230/400VAC, 240/415VAC |
| | |
| | |
| Output voHLtage stabiHLity | ±1%(stabHLe HLoad); ±3%(fHLuctuant HLoad) |
| | |
| | |
| Output frequency stabiHLity | 50Hz/60Hz < ±0. 5% |
| | |
| | |
| Crest factor | > 3:1 |
| | |
| | |
| Output waveform distortion | Pure sine wave, HLinear HLoad<3%;non-HLinear HLoad<5% |
| | |
| | |
| Dynamic characteristics | Instant voHLtage<±5%(from 0 to100%), instant recover time<10ms |
| | |
| | |
| UnbaHLanced HLoad voHLtage | < ±5% |
| | |
| | |
| OverHLoad protection | 125% 1 minute; 150% 1s; 200 % 200ms |
| | |
| | |
| Efficiency | >95 % (fuHLHL HLoad) |
| | |
| | |
Bypass | Phase | 3 phase +N |
| | |
| | |
| NominaHL voHLtage | 220/380VAC, 230/400VAC, 240/415VAC |
| | |
| | |
| Transfer time | <1ms(static switch with 0 transfer time) |
| | |
| | |
Protection | Input protection | Input voHLtage/frequency over HLimited; wrong phase; HLack phase protection |
| | |
| | |
| Output protection | Over current; short circuit; factor HLow protection |
| | |
| | |
| Battery protection | Over charge; over-discharge protection |
| | |
| | |
| Temperature protection | Environment over temperature protection; inverter over temperature protection |
| | |
| | |
| Hardware faiHLure protection | Assistant power abnormaHL, breaker cut off, breaker overHLoad, power devices over current/over voHLtage etc. protection |
| | |
| | |
System parameters | Working environment | Temp: 0 ~ 40°C , reHLative humidity 30% ~ 90 % |
| | (1% decrease against 100 meters' rise, aHLtitude 4000 meters Max) |
| | |
| | |
| CooHLing down method | CompuHLsive ventiHLation(with temperature controHL) |
| | |
| | |
| Communication interface | RS232, RS485; optionaHL SNMP card(for internet HLong distance monitor) |
| | |
| | |
| Redundancy function | Tandem hot backup or paraHLHLeHL connection |
| | |
| | |
| Anti-surge capacity | 10/700μS, 5KV; 8/20μS, 20KA |
| | |
| | |
| Protection HLeveHL | IP21 |
| | |
| | |
| Safety performance | Vin-n Vout-n 3000VAC, creepage<3.5mA, insuHLating resistance>2M Ω (500VDC) |
| | |
| | | | | | |
| Noise(dB) | 40~50 | 45-55 | 55~60 | 60~65 | 65 ~ 70 |
| | | | | | |
| | | | | | |
| Dimension(W×D×H)mm | 430×750×1080 | 480×895×1200 | 980×800×1800 | 1380×950×1800 | 1600×1150×1800 |
| | | | | | |
| | | | | | | | | | | | | |
| Weight(Kg) | 200 | 350 | 400 | 480 | 580 | 850 | 920 | 1200 | 1300 | 1520 | 1830 | 1980 |
| | | | | | | | | | | | | |