High Frequency ONLINE UPS 110V 220V
Function Features
1.True double-conversion online UPS
A true double conversion UPS will provide clean, high level quality power to fully protect mission-critical devices such as sensitive networks, small computer centers, servers, telecom applications, as well as for industrial applications.
2. Output power factor 0.8
Compared to the online UPS in the current market, Venus series UPS provides better output power factor up to 0.8. It offers higher performance and effciency for critical applications.
3. Wide input voltage range (110V-300V)
Venus series can still provide stable power to connected devices under unstable power environments.
4. 50/60 Hz Frequency Converter Mode
Lock output frequency at 50Hz or 60Hz to suit power sensitive equipments.
5. ECO mode operation for energy saving
Offers efficiency as high as 97% to cut energy usage &cost. UPS power application via static bypass, timely returning to online double conversion when the need arises.
6.Emergency Power Off (EPO) Function
This feature can secure the personnel and equipment in case of fires or other emergencies.
7.USB+RS232+RJ45+SNMP,multiple communication for 1-3K models
This feature allows either USB,RS232 or Rj45 communication port to work with SNMP interface simultaneously.
8. DSP technology applied for 6-10K models
A DSP controller provides an improved and cost-effective solution with high performance.
Monitoring Software
? UPS can be connected to the computer via USB or Rs232 interface. So it can be realized LAN monitoring single or many sets of UPS, it also can monitor the other ups which connected to the computer via LAN.
? UPS monitoring software has more than 10 kinds of language for choice.
? Humanized operation interface, which is powerful and can shows the battery voltage, frequency, load, temperature and other data by real-time monitoring through the charts.
? Alarm of different power incident could be set by radio, mobile phone text messages, e-mails and SNMP etc.
Technical Specification
High Frequency Tower UPS |
MODEL | PHT1101 | PHT1102 | PHT1103 | PHT1101B | PHT1102B | PHT1103B |
CAPACITY | 1000 VA / 800 W | 2000 VA / 1600 W | 3000 VA / 2400 W | 1000 VA / 800 W | 2000 VA / 1600 W | 3000 VA / 2400 W |
Battery Voltage | 36V | 72V | 36V | 72V |
Size, D X W X H (mm) | 282 X 145 X 220 | 397 X 145 X 220 | 397 X 145 X 220) | 419 X 190 X 318 |
Net Weight (kgs) | 4.1 | 6.8 | 7.4 | 13 | 26 | 28 |
INPUT |
Voltage Range | Low Line Transfer | 160VAC/140VAC/120VAC/110VAC±5% |
Low Line Comeback | 175VAC/155VAC/135VAC/125VAC ± 5 % | 168 VAC / 148VAC / 128 VAC / 118 VAC ± 5 % |
High Line Transfer | 300 VAC ± 5 % |
High Line Comeback | 290 VAC ± 5 % |
Frequency Range | 40Hz ~ 70 Hz |
Phase | Single phase with ground |
Power Factor | ≥ 0.99 @ nominal voltage (input voltage) |
OUTPUT |
Output voltage | 200/208/220/230/240VAC |
AC Voltage Regulation | ± 1% (Batt. Mode) |
Frequency Range (Synchronized Range) | 47Hz ~ 53 Hz @ 50Hz 57Hz ~ 63 Hz @ 60Hz |
Frequency Range (Batt. Mode) | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz |
Overload | 105%~110%: UPS shuts down after 10 min at battery mode or transfer to bypass when the utility is normal 110%~130%: UPS shuts down after 1min at battery mode or transfer to bypass when the utility is normal >130%:UPS shuts down after 3seconds at battery mode or transfer to bypass when the utility is normal | 100%~110%:audible warning 110%~130%: UPS shuts down in 60 seconds at battery mode or transfer to bypass when the utility is normal >130%:UPS shuts down immediately at battery mode or transfer to bypass mode when the utility is normal |
Current Crest Ratio | 3:1 |
Harmonic Distortion | ≤ 3 % THD (Linear Load);≤ 5% THD (Non-linear Load) | ≤ 3 % THD (linear load);≤ 6 % THD (non-linear load) |
Transfer Time | AC Mode to Batt. Mode | 0 ms |
Inverter to Bypass | 4 ms |
Waveform (Batt. Mode) | Pure Sine Wave |
EFFICIENCY |
AC Mode | 88% | 89% | 90% | 87% | 90% |
Battery Mode | 83% | 87% | 88% | 83% | 87% | 89% |
BATTERY |
Battery Type | Depending on applications | 12V7AH | 12V7AH | 12V9AH |
Battery Numbers | Depending on applications | 3 | 6 | 6 |
Recharge Time | Depending on applications | 4 hours recover to 90% capacity |
Charging Current | 1.0A/2.0A/4.0A/6.0 A | 1.0 A (max.) |
Charging Voltage | 41.0VDC ± 1% | 82.1 VDC ±1% | 82.1 VDC ±1% | 41.0VDC ± 1% | 82.1 VDC ±1% | 82.1 VDC ±1% |
ENVIRONMENT |
Operation Humidity | 20-90 % RH @ 0- 40°C (non-condensing) |
Noise Level | Less than 50dBA @ 1 Meter |
MANAGEMENT |
Smart RS-232 or USB | Windows® 2000/2003/XP/Vista/2008,Windows® 7/8,Linux,Unix,MAC |
Optional SNMP | Power management from SNMP manager and web browser |