Power Supply Uninterruptible Power Supply 3Kva Ups
3kva ups Key features:
H series on-line UPS is an advanced true double conversion on-line topology, the H series isolated gate bipolar transistors (IGBT) for true isolation from AC input. Ideal for data centers in network and industrial applications. Features scalable battery packs for those critical business systems that require long run times. With the H series wide in-put voltage range and near zero tolerance on frequency and voltage variance on the put-put the H series is perfect for the most demanding and delicate of applications.
a). Sine-wave output
True sine-wave output with less than 3% THD
b). Double conversion design
Zero transfer/complete isolation of input AC
c). UPS monitoring software
Powerful true RS232 communication via the enclosed software manages and safely shutdown operating systems.
d). Network RJ45/11 protection
Completed powerful network and phone line surge protection
e). AC surge suppressor
Powerful multi-stage surge components exceed IEEE requirements.
f). SNMP slot option
Allows for remote monitoring and control via www
g). Sleep mode
Worry free battery management. The unit turns itself off after ten seconds to conserve battery power when no power needs are detected.
h). Battery level indicators
LED's indicate battery levels
i). Load sensing
The incorporated LED load indicators allow IT professionals to manage backup time and balance power loads.
j). Low battery indicators
The low battery level indicator will warn of eminent UPS shutdown two full minutes before unit shuts down.
k). Replace battery indicators
A preventative measure that indicates when batteries must be replaced to prevent server crashes.
Model | H1KS | H2KS | H3KS |
Rated power | VA/W | 1KVA/0.7KW | 2KVA/1.4KW | 3KVA/2.1KW |
Input | Nominal voltage | 220VAC |
Voltage range | 115~300VAC |
Frequency range | 46~54Hz(default), user adjustable within 40~60Hz |
Power efficiency | 0.97 |
Connection | IEC320-10A inlet | IEC320-16A inlet |
Output | Voltage | 220VAC±2% |
Frequency | 46~54Hz or 50Hz±0.2(line mode) 50Hz±0.2Hz(battery mode) |
Waveform | Pure sine wave |
Distortion | 3% | 4% |
Overload capability | 108%~150% for 30 sec., 150% for 300ms |
Current crest ratio | 3:1 |
Connection | IEC320*4 | IEC320*6 | IEC320*3 and terminal block |
Battery | Type | Sealed, maintenance free, lead-acid |
Quantity | 3 pieces | 6 pieces | 8 pieces |
Back-up time(full load) | 5 min | 9 min | 5 min |
Recharge time | 5 hrs to 90% of capacity after full load discharge |
Bypass | Automatic transfer | On overload and UPS failure |
Before UPS power-on | Default "NO", user adjustable to "YES" |
Voltage range | 80~264VAC(default), user adjustable within 80~286VAC |
Transfer time | 0 ms; less than 4ms from inverter to bypass and vice versa |
LED indicators | Status | Load level/battery level, battery , utility power, inverter, bypass, overload, fault |
Audible alarm | Bypass, on battery mode, battery low, overload, fault |
Acoustic noise | At 1 meter distance | 45 dB | 50 dB |
Communication | DB-9 port | RS-232 serial interface |
Intelligent slot | Options: Webpower, AS400 card or Winpower CMC |
Network surge protection | RJ45 I/O port available for network or fax/modem |
Environmental | Operating temperature | 0~40°C |
Operating humidity | 20~90% non-condensing |
Weight | Net(Kg) | 13 | 31.5 | 32 |
Dimension | WxDxH(mm) | 145x400x220 | 192x460x348 |
Model | H1KL | H2KL | H3KL |
Rated power | VA/W | 1KVA/0.7KW | 2KVA/1.4KW | 3KVA/2.1KW |
Input | Nominal voltage | 220VAC |
Voltage range | 115~300VAC |
Frequency range | 46~54Hz(default), user adjustable within 40~60Hz |
Power factor | 0.97 |
Connection | IEC320-10A inlet | IEC320-16A inlet |
Output | Voltage | 220VAC±2% |
Frequency | 46~54Hz or 50Hz±0.2(line mode) 50Hz±0.2Hz(battery mode) |
Waveform | Pure sine wave |
Distortion | 3% | 4% |
Overload Capability | 108%~150% for 30 sec., 150% for 300ms |
Current crest ratio | 3:1 |
Connection | IEC320-10A*4 | IEC320-10A*6 | IEC320-10A*3 and terminal block |
Battery | Type | Sealed, maintenance free, lead-acid |
Nominal DC voltage | 36VDC | 96VDC | 96VDC |
Back-up time | Depends on the capacity of the external battery bank |
Connection | External battery socket |
Bypass | Automatic transfer | On overload and UPS failure |
Before UPS power-on | Default "NO", user adjustable to "YES" |
Voltage range | 80~264VAC(default), user adjustable within 80~ 286VAC |
Transfer time | 0 ms; less than 4 ms from inverter to bypass and vice versa |
LED indicators | Status | Load level/battery level, battery, utility power, inverter, bypass, overload, fault |
Audible alarm | Bypass, on battery mode, battery low, overload, fault |
Acoustic noise | At 1 meter distance | 45 dB | 50 dB |
Communication | DB-9 port | RS-232 serial interface |
Intelligent slot | Options: WebPower, AS400 card or WinPower CMC |
Network surge protection | RJ45 I/O port available for 10 base-T network or fax/modem |
Environmental | Operating temperature | 0~40°C |
Operating humidity | 20~90% non-condensing |
Weight | Net(Kg) | 7 | 13.5 | 14 |
Dimension | W x D x H(mm) | 145x400x220 | 192x460x348 |