High Frequency Online UPS 110V OUTPUT
Online 3kva 2kva 1kva ups 110v
H series on-line UPS is an advanced true double conversion on-line topology, the H series isolated gate bipolar transistors (IGBT) for true isolation from AC input. Ideal for data centers in network and industrial applications. Features scalable battery packs for those critical business systems that require long run times. With the H series wide in-put voltage range and near zero tolerance on frequency and voltage variance on the put-put the H series is perfect for the most demanding and delicate of applications.
Sine-wave output
True sine-wave output with less than 3% THD.
Double conversion design
Zero transfer/complete isolation of input AC.
UPS monitoring software
Powerful true RS232 communication via the enclosed software to manage and safely shutdown operating systems.
Network RJ45/11 protection
Complete powerful network and phone line surge protection.
AC surge suppressor
Powerful multi-stage surge components that exceed IEEE requirements.
SNMP slot option
Allows for remote monitoring and control via www.
Sleep mode
Worry free battery management. The unit turns itself off after ten seconds to conserve battery
Power when no power needs are detected.
Batterylevel indicators
LED's indicate battery levels.
Load sensing
The incorporated LED load indicators allow IT professionals to manage backup time and balance power loads.
Low battery indicators
The low battery level indicator will warn of eminent UPS shutdown two full minutes before unit shuts down.
Replace battery indicators
A preventative measure that indicates when batteries must be replaced to prevent server crashes.
1. True double-conversion online UPS
A true double conversion UPS will provide clean, high level quality power to fully protect mission-critical devices such as sensitive networks, small computer centers, servers, telecom applications, as well as for industrial applications.
2. Wide input voltage range (115V-300V)
HF series can still provide stable power to connected devices under unstable power environments.
3.50/60 Hz Frequency Converter Mode
Lock output frequency at 50Hz or 60Hz to suit power sensitive equipments.
4. ECO mode operation for energy saving
Offers efficiency as high as 97% to cut energy usage & cost. UPS power application via static bypass, timely returning to online double conversion when the need arises.
5. Emergency Power Off (EPO) Function
This feature can secure the personnel and equipment in case of fires or other emergencies.
Monitoring Software
UPS can be connected to the computer via USB or Rs232 interface. So it can be realized LAN monitoring single or many sets of UPS, it also can monitor the other ups which connected to the computer via LAN.
UPS monitoring software has more than 10 kinds of language for choice.
Humanized operation interface, which is powerful and can shows the battery voltage, frequency, load, temperature and other data by real-time monitoring through the charts.
Alarm of different power incident could be set by radio, mobile phone text messages, e-mails and SNMP etc.
Model | H1KS | H2KS | H3KS |
Rated power | VA/W | 1KVA/0.7KW | 2KVA/1.4KW | 3KVA/2.1KW |
Input | Nominal voltage | 220VAC |
Voltage range | 115~300VAC |
Frequency range | 46~54Hz(default), user adjustable within 40~60Hz |
Power factor | 0.97 |
Connection | IEC320-10A inlet | IEC320-16A inlet |
Output | Voltage | 220VAC±2% |
Frequency | 46~54Hz or 50Hz±0.2(line mode) 50Hz±0.2Hz(battery mode) |
Waveform | Pure sine wave |
Distortion | 3% | 4% |
Overload capability | 108%~150% for 30 sec., 150% for 300ms |
Current crest ratio | 3:1 |
Connection | IEC320*4 | IEC320*6 | IEC320*3 and terminal block |
Battery | Type | Sealed, maintenance free, lead-acid |
Quantity | 3 pieces | 6 pieces | 8 pieces |
Back-up time(full load) | 5 min | 9 min | 5 min |
Recharge time | 5 hrs to 90% of capacity after full load discharge |
Bypass | Automatic transfer | On overload and UPS failure |
Before UPS power-on | Default "NO", user adjustable to "YES" |
Voltage range | 80~264VAC(default), user adjustable within 80~286VAC |
Transfer time | 0 ms; less than 4ms from inverter to bypass and vice versa |
LED indicators | Status | Load level/battery level, battery , utility power, inverter, bypass, overload, fault |
Audible alarm | Bypass, on battery mode, battery low, overload, fault |
Acoustic noise | At 1 meter distance | 45 dB | 50 dB |
Communication | DB-9 port | RS-232 serial interface |
Intelligent slot | Options: Webpower, AS400 card or Winpower CMC |
Network surge protection | RJ45 I/O port available for network or fax/modem |
Environmental | Operating temperature | 0~40°C |
Operating humidity | 20~90% non-condensing |
Weight | Net(Kg) | 13 | 31.5 | 32 |
Dimension | WxDxH(mm) | 145x400x220 | 192x460x348 |